Having completed all relevant preliminary electrical safety checks to boiler and pipework confirming safe isolation and earth path, isolate central heating system and drain.
|
|

Identify location for installation of MagnaClean filter. Prepare pipework, installing MagnaClean copper elbows and isolation valves supplied. N.B. Refer to MagnaClean installation instructions.
|
|

Having completed the installation of the MagnaClean, remove the filter and attach the MagnaCleanse hoses between the PowerFlushing Filter and the MagnaClean isolation valves on the pipework.
|
|

Turn off isolation valves to the PowerFlushing Filter. Loosen and remove the lid assembly from one of the PowerFlushing Filter canisters.
|
|

Add recommended cleanser to the system via the PowerFlushing Filter canister.
|
|

Partly re-fill the central heating system ensuring the radiators are only half-full. Check for leaks.
|
|

Turn on heating system (all radiators open) for 15 minutes. The radiators should be hot at the bottom, cold at the top. Check filters if required.
|
|

Turn off any by-pass valves and all the radiators leaving only one radiator open at a time. With the system running, agitate each radiator using ADEY’s VibraClean tool attached to a standard SDS drill for 15–20 seconds.
|
|

Continue the VibraClean radiator agitation to dislodge any sludge deposits until the return hose to the PowerFlushing Filter runs clear (usually 5 minutes).
|
|

Isolate and clean the PowerFlushing Filter as required. Using Personal Protective Equipment i.e. gloves and paper towels, wipe off any magnetite into a bucket or waste bag and dispose of correctly. When satisfied, open up the next radiator, then turn off the treated radiator and repeat the process until all radiators are clean.
|
|

Once the MagnaCleanse process has been completed, fill the system radiators from half-full removing all air. For sealed systems, check the system pressure and increase to 1 bar if required. Run for 10 minutes full with all radiators open, then drain the whole system.
|
|

Disconnect hoses and remove the PowerFlushing Filter. Re-attach the MagnaClean domestic filter to the isolation valves.
|
|

Add a recommended inhibitor into the canister i.e. use the Pro-Fill bleed valve or remove canister lid assembly and pour into the filter (holds approximately half a litre). Open up the isolation valves and remove any air.
|
|

Turn on the system and re-set controls to the customer requirements. Open any by-pass valves previously closed.
|
|

Commission the system following the manufacturer’s instructions. Before leaving the property, carry out the last job – Service the MagnaClean filter ensuring a final check is carried out for leaks.
|
| |
|
|
|
|
| |
|
|
|
|